11. Cooler and Condenser Tubes:

11. Cooler and Condenser Tubes:

 

 

 

18. Optional Compressor Discharge Isolation Valve

Contact a local Carrier Representative for other

 

and Liquid Line Ball Valve:

 

 

tube offerings.

 

 

 

 

 

These items shall be factory-installed to allow

12. Cooler and Condenser Passes:

 

 

 

isolation of the refrigerant charge in the con-

 

 

 

denser for servicing the compressor.

 

Unit manufacturer shall provide the cooler and/

 

 

 

19. Pumpout Unit:

 

 

 

 

 

or condenser with 1, 2 or 3 pass configuration

 

 

 

 

 

 

on the water side.

 

 

 

 

 

A refrigerant pumpout system shall be installed

13. Nozzle-In-Head, 300 psig (2068 kPa):

 

 

on

the

chiller.

The

pumpout

system shall

 

 

include a hermetic compressor and drive, inter-

Unit manufacturer shall furnish nozzle-in-head

 

 

nal

piping, internal wiring, and

motor. Field-

style

waterboxes on the

cooler

and/or

con-

 

 

supplied main power wiring and water piping

denser rated at 300 psig (2068 kPa).

 

 

 

 

shall be required.

 

 

 

 

14. Marine Waterboxes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20. BACnet Communication Option:

 

 

Unit

manufacturer

shall

furnish

marine

style

 

 

 

 

Shall provide factory

installed communication

waterboxes on cooler and/or condenser rated

 

 

capability with

a

BACnet MS/TP

network.

at 150 psig (1034 kPA).

 

 

 

 

 

 

 

 

Allows integration with i-Vu®Open control sys-

15. Marine Waterboxes:

 

 

 

 

 

 

 

 

 

 

tem or a BACnet building automation system.

Unit manufacturer shall furnish marine style

 

denser for servicing the compressor.

 

waterboxes on cooler and/or condenser rated

21. Optional Seismic Isolation Package:

 

at 300 psig (2068 kPA).

 

 

 

 

 

 

 

 

Package shall meet International Building Code

16. Flanged Water Nozzles:

 

 

 

 

 

 

 

 

and ASCE 7 seismic qualification requirements

Unit manufacturer shall furnish standard

 

 

in concurrence with ICC ES AC156 Accep-

flanged piping connections on the cooler and/

 

tance Criteria for Seismic Qualification by

or condenser.

 

 

 

 

 

Shake-Table Testing of Nonstructural Compo-

17. Hinges:

 

 

 

 

 

nents and Systems. Manufacturer shall provide

Unit

manufacturer

shall

furnish

hinges

on

 

seismic

certificate

from OSHPD

(California

 

only).

 

 

 

 

 

 

waterboxes to facilitate tube cleaning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 