Carrier 48TF004-007 START-UPCHECKLIST Remove and Use in Job File, I. Preliminary Information

Models: 48TF004-007

1 52
Download 52 pages 21.55 Kb
Page 52
Image 52
START-UP CHECKLIST

START-UP CHECKLIST

(Remove and Use in Job File)

I. PRELIMINARY INFORMATION:

MODEL NO.: _________________________________

SERIAL NO.: ______________________________________

DATE: _______________________________________

TECHNICIAN: ____________________________________

 

BUILDING LOCATION: _____________________________

II.PRE-START-UP (insert checkmark in box as each item is completed)

VERIFY THAT ALL PACKING MATERIALS HAVE BEEN REMOVED FROM UNIT

REMOVE ALL SHIPPING HOLDDOWN BOLTS AND BRACKETS PER INSTALLATION INSTRUCTIONS VERIFY THAT CONDENSATE CONNECTION IS INSTALLED PER INSTALLATION INSTRUCTIONS VERIFY THAT FLUE HOOD IS INSTALLED

CHECK ALL ELECTRICAL CONNECTIONS AND TERMINALS FOR TIGHTNESS

CHECK TO ENSURE NO WIRES ARE TOUCHING REFRIGERANT TUBING OR SHARP EDGES CHECK GAS PIPING FOR LEAKS

CHECK THAT INDOOR-AIR FILTER IS CLEAN AND IN PLACE VERIFY THAT UNIT INSTALLATION IS LEVEL

￿CHECK FAN WHEEL AND PROPELLER FOR LOCATION IN HOUSING/ORIFICE AND SETSCREW TIGHTNESS VERIFY PULLEY ALIGNMENT AND BELT TENSION ARE CORRECT

III. START-UP:

ELECTRICAL

 

 

 

 

 

 

SUPPLY VOLTAGE

L1-L2

_________

L2-L3

__________

L3-L1

__________

COMPRESSOR AMPS

L1

_________

L2

__________

L3

__________

INDOOR-FAN AMP

L1

_________

L2

__________

L3

__________

TEMPERATURES

 

 

 

 

OUTDOOR-AIR TEMPERATURE

__________

DB

_________

WB

RETURN-AIR TEMPERATURE

__________

DB

_________

WB

COOLING SUPPLY AIR

__________

DB

_________

WB

GAS HEAT SUPPLY AIR

__________

DB

 

 

PRESSURES

 

 

 

 

GAS INLET PRESSURE

__________

IN. WG

 

 

GAS MANIFOLD PRESSURE

__________

IN. WG (LOW FIRE)

________

IN. WG (HI FIRE)

REFRIGERANT SUCTION

__________

PSIG

________

TEMP ° F

REFRIGERANT DISCHARGE

__________

PSIG

________

TEMP ° F

￿VERIFY REFRIGERANT CHARGE USING CHARGING TABLES

VERIFY THAT 3-PHASE SCROLL COMPRESSOR IS ROTATING IN CORRECT DIRECTION (48TF007 ONLY)

Copyright 2000 Carrier Corporation

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

PC 111

Catalog No. 534-80000

Printed in U.S.A.

Form 48TF-1SI

Pg CL-1

8-00

Replaces: New

Tab

1a

6a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - CUT ALONG DOTTED LINECUT ALONG DOTTED LINE

Page 52
Image 52
Carrier 48TF004-007 START-UPCHECKLIST Remove and Use in Job File, I. Preliminary Information, Iii. Start-Up, Electrical