Table 14 — Fan Performance 48TF006 — Vertical Discharge Units, Standard Motor

48TF006 (5 TONS) — STANDARD MOTOR (DIRECT DRIVE)

Airflow

 

 

Low Speed

 

 

 

 

 

 

 

 

Medium Speed

 

 

 

 

 

 

 

High Speed

 

 

 

 

 

208 V

 

 

230,460,575 V

 

 

 

208 V

 

 

230,460,575 V

 

 

 

208 V

 

230,460,575 V

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Esp

Bhp

Watts

Esp

 

Bhp

 

Watts

Esp

 

Bhp

Watts

Esp

 

Bhp

 

Watts

Esp

 

Bhp

 

Watts

Esp

 

Bhp

 

Watts

1500

0.69

0.67

750

 

1.01

 

0.71

 

791

 

1.00

 

0.70

782

 

1.20

 

0.76

 

845

 

1.22

 

0.79

 

875

 

1.28

 

0.85

 

949

1600

0.49

0.70

780

 

0.85

 

0.74

 

824

 

0.85

 

0.74

821

 

1.06

 

0.79

 

883

 

1.09

 

0.82

 

913

 

1.17

 

0.89

 

988

1700

0.29

0.73

810

 

0.70

 

0.77

 

857

 

0.70

 

0.77

861

 

0.93

 

0.83

 

921

 

0.97

 

0.85

 

950

 

1.06

 

0.92

 

1027

1800

0.09

0.75

839

 

0.54

 

0.80

 

891

 

0.55

 

0.81

900

 

0.80

 

0.86

 

959

 

0.84

 

0.89

 

988

 

0.95

 

0.96

 

1066

1900

0.39

0.83

 

924

0.40

0.84

940

0.67

0.90

997

0.72

0.92

 

1025

0.84

0.99

1105

2000

0.23

0.86

 

957

0.25

0.88

979

0.54

0.93

1035

0.59

0.95

 

1063

0.73

1.03

1144

2100

0.08

0.89

 

990

0.10

0.91

1018

0.41

0.96

1073

0.46

0.99

 

1101

0.62

1.06

1183

2200

 

 

 

0.28

1.00

1111

 

0.34

 

1.02

1138

 

0.51

 

1.10

1222

 

 

2300

 

 

 

0.15

1.03

1149

 

0.21

 

1.06

1176

 

0.40

 

1.13

1261

 

 

2400

 

 

 

0.02

1.07

1187

 

0.09

 

1.09

1213

 

0.29

 

1.17

1300

 

 

2500

 

 

 

 

0.18

1.20

1340

 

 

 

LEGEND

Bhp — Brake Horsepower Input to Fan

Esp — External Static Pressure (in. wg)

FIOP — Factory-Installed Option

NOTES:

1.Values include losses for filters, unit casing, and wet coils. See Table 7 for accessory/FIOP static pressure information.

2.Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Table 6 — Motor Data for Additional information.

3.Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative for details.

Table 15 — Fan Performance 48TF006 — Vertical Discharge Units, Alternate Motor

48TF006 (5 TONS) — ALTERNATE MOTOR (BELT DRIVE)*

Airflow

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.1

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

729

0.36

368

788

0.42

429

896

 

0.56

572

981

0.69

705

1070

0.85

869

1144

1.01

1032

1600

770

0.42

429

826

0.49

501

930

 

0.64

654

1015

0.78

797

1098

0.94

961

1173

1.11

1134

1700

811

0.50

511

864

0.57

582

964

 

0.72

736

1051

0.88

899

1124

1.03

1053

1203

1.21

1237

1800

852

0.58

593

903

0.66

674

999

 

0.82

838

1085

0.98

1001

1155

1.13

1155

1231

1.32

1349

1900

893

0.68

695

942

0.76

777

1035

 

0.92

940

1119

1.10

1124

1191

1.26

1288

1288

1.43

1461

2000

935

0.78

797

982

0.87

889

1070

 

1.04

1063

1153

1.22

1247

1227

1.40

1431

1287

1.57

1604

2100

977

0.89

910

1022

0.99

1012

1107

 

1.17

1196

1187

1.35

1380

1260

1.54

1574

1323

1.72

1758

2200

1019

1.02

1042

1063

1.12

1145

1144

 

1.30

1328

1222

1.49

1523

1294

1.70

1737

1359

1.89

1931

2300

1061

1.16

1185

1104

1.26

1288

1182

 

1.47

1502

1258

1.65

1686

1328

1.80

1901

1393

2.07

2115

2400

1103

1.30

1328

1145

1.41

1441

1220

 

1.61

1645

1293

1.80

1860

1362

2.03

2074

1426

2.26

2310

2500

1145

1.46

1492

1186

1.57

1604

1259

 

1.78

1819

1329

2.00

2044

1397

2.22

2269

1460

2.45

2504

48TF006 (5 TONS) — ALTERNATE MOTOR (BELT DRIVE)* (cont)

External Static Pressure (in. wg)

Airflow

 

 

1.2

 

 

 

1.4

 

 

 

1.6

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

1500

 

1226

1.19

1216

 

1301

1.46

1492

 

1380

1.69

1757

1600

 

1242

1.28

1308

 

1318

1.49

1523

 

1392

1.78

1800

1700

 

1270

1.39

1420

 

1335

1.58

1615

 

1408

1.80

1850

1800

 

1300

1.52

1553

 

1361

1.71

1747

 

1423

1.91

1952

1900

 

1329

1.64

1676

 

1391

1.80

1891

 

1448

2.05

2095

2000

 

1355

1.77

1809

 

1420

1.99

2034

 

1477

2.21

2258

2100

 

1381

1.91

1952

 

1449

2.14

2167

 

2200

 

1413

2.08

2126

 

1474

2.30

2350

 

2300

 

1449

2.26

2310

 

 

2400

 

1485

2.47

2524

 

 

2500

 

 

 

LEGEND

Bhp — Brake Horsepower Input to Fan

FIOP — Factory-Installed Option

Watts — Input Watts to Motor

*Motor drive range is 900 to 1300 rpm. All other rpms require a field- supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2. indicates field-supplied motor and drive are required.

3.Values include losses for filters, unit casing, and wet coils. See Table 7 for accessory/FIOP static pressure information.

4.Maximum continuous bhp is 1.30 for single-phase units and 2.40 for 3-phase units and the maximum continuous watts are 2120. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Table 6 — Motor Data for additional information.

5.Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative for details.

6.Interpolation is permissible. Do not extrapolate.

24

Page 24
Image 24
Carrier 48TF004-007 specifications 48TF006 5 Tons Standard Motor Direct Drive, 48TF006 5 Tons Alternate Motor Belt Drive

48TF004-007 specifications

The Carrier 48TF004-007 is part of the brand's renowned rooftop unit series, designed to deliver efficient, reliable performance for commercial applications. Ideal for spaces such as offices, retail stores, and small manufacturing facilities, these units encapsulate advanced technology to enhance indoor air quality and optimize climate control.

One of the standout features of the Carrier 48TF004-007 units is their variable speed compressor technology. This innovation not only allows for precise temperature control but also reduces energy consumption by modulating the compressor's speed according to the cooling or heating demand. By operating at lower speeds during less demanding conditions, these units significantly decrease energy usage compared to traditional single-speed compressors, contributing to lower utility bills and a reduced carbon footprint.

Energy efficiency is further enhanced with the inclusion of high-performance scroll compressors, which are known for their reliable operation and quiet performance. Coupled with an Energy Efficiency Ratio (EER) that meets or exceeds industry standards, these systems are designed to offer economical operation without sacrificing comfort.

Incorporating smart controls and connectivity features, the Carrier 48TF004-007 units allow for easy integration into building management systems (BMS). This enhances the ability to monitor and manage energy usage in real time, further promoting efficiency. The units are also compatible with various thermostat options, allowing for user-friendly operation and customization of settings.

Another significant characteristic of the Carrier 48TF004-007 is its durable construction. Built with galvanized steel and powder-coated finishes, these units are designed to withstand the rigors of outdoor installation, ensuring long-lasting performance even in harsh weather conditions. Additionally, the units come equipped with advanced filtration systems that help improve indoor air quality by effectively removing dust, allergens, and other particulate matter from the air.

Maintenance is simplified with the Carrier 48TF004-007, providing easy access to vital components, which supports reduced downtime and service costs. The units also feature low operating sound levels, making them suitable for noise-sensitive applications.

In conclusion, the Carrier 48TF004-007 rooftop units stand out for their energy efficiency, advanced technology, durability, and ease of maintenance, making them an excellent choice for any commercial space looking to enhance comfort while effectively managing operational costs.