Carrier 48TF004-007 Wiring Connections for, Outdoor-AirThermostat, Durablade Economizer

Models: 48TF004-007

1 52
Download 52 pages 21.55 Kb
Page 14
Image 14
Fig. 23 — Wiring Connections for

LEGEND

OAT — Outdoor-Air Thermostat

NOTE: See unit wiring diagram for details.

Fig. 23 — Wiring Connections for

Outdoor-Air Thermostat

 

0.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wg)(in.

0.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DROP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

200

300

400

500

600

700

800

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

 

 

 

Fig. 24 — Durablade Economizer

Barometric Relief Damper Characteristics

OPTIONAL ECONOMI$ER — See Fig. 25 for Ec onoMi$er component locations.

1.To remove the existing unit filter access panel, raise the panel and swing the bottom outward. The panel is now disengaged from the track and can be removed. Remove the indoor coil access panel and discard. See Fig. 26.

If installing an optional Power Exhaust Assembly, refer to the EconoMi$er Power Exhaust Installation Instructions.

Controller should be mounted in vertical position as shown in Fig. 25.

2.Assemble the hood assembly as follows:

Remove the EconoMi$er hood from its packaging. Re- move shipping brackets holding hood package to EconoMi$er. Locate the outdoor-air opening panel. See Fig. 27. Remove hood assembly shipping brackets locat- ed on the back (sloped) side of the EconoMi$er assembly. These brackets are used to retain the hood assembly dur- ing shipping only.

3.Installs the 1/8 x 3/4-in. seal strip on the exhaust air hood side panels and the bottom bracket. Assemble the exhaust air hood to the outdoor-air opening panel as shown in Fig. 27, using the screws provided. Do not attach hood assembly to unit at this time.

4.Install the 1/8 x 3/4-in. seal strip on the outdoor-air hood top and side panels. Assemble the outdoor-air hood to the outdoor-air opening panel as shown in Fig. 28, using the screws provided. Do not attach hood assembly to the unit

at this time.

ECONOMI$ER

CONTROLLER

PLUG

GEAR-DRIVEN

 

 

DAMPER

OUTDOOR AIR

TEMPERATURE

SENSOR

Outdoor-Air Thermostat ACTUATOR

BAROMETRIC RELIEF DAMPERS

Fig. 25 — EconoMi$er Component Locations

OUTDOOR-AIR

FILTER ACCESS

OPENING PANEL

PANEL

Fig. 26 — Typical Access Panel Locations

OUTDOOR AIR

OPENING PANEL Fig. 24 — Durablade EconomizerBarometric Relief Damper CharacteristicsEXHAUST AIR HOOD TOP

SCREEN

RETAINER

 

EXHAUST AIR

SEAL STRIP

HOOD SIDES

 

at this time. EXHAUST AIR SCREEN

EXHAUST AIR BOTTOM BRACKET

Fig. 27 — Exhaust Air Hood Assembly

14