Electrical Installation & Cabling

Reset Button

Reset Button

The system can be reset by pressing the reset button located on the front panel.

Alarm/Status LEDs

LED

State

Description

Critical

Off

No critical alarms present

 

 

 

 

Red

Critical alarms present. Critical alarms include:

 

 

user-configured manor environmental inputs.

 

 

 

Major

Off

No major alarms present

 

 

 

 

Red

Major alarm present. Major alarms include:

 

 

user-configured manor environmental inputs, DS1 short, DS1 open, DS1

 

 

facility alarm, DS1 RAI, DS1 AIS, DS1 LOF, DS1 LOS, WAN fault,

 

 

Ethernet fault and dead card alarms.

 

 

 

Minor

Off

No minor alarms present

 

 

 

 

Red

Minor alarms present. Minor alarms include:

 

 

user-configured minor environmental inputs, DS1 excessive line code

 

 

violations.

 

 

 

Status

Off

No power to system

 

 

 

 

Green

Application running, no detected system problems.

 

 

 

 

Green Flashing

Power-On Self Test (POST) successful. System booted. Loading

 

 

Application.

 

 

 

 

Green/Yellow

Flashing alternate colors. Application Self Test in Process.

 

 

 

 

Yellow

Yellow while booting. If this stays a steady yellow the Power-On Self Test

 

 

(POST) failed.

 

 

 

 

Yellow Flashing

Power-On Self Test (POST) In Process.

 

 

 

 

Red

System Failure

 

 

 

Adit 3104 - Release 1.6

3-9

Page 39
Image 39