Changing Wire Settings

1.WARNING! Make sure to turn off the Welder and unplug it from its electrical outlet prior to changing wire settings.

2.Lift the Door (14A) of the Welder to expose the Wire Feed Assembly.

3.Loosen, and lower the Handle (4D) on the Wire Feed Assembly.

4.Remove the Screw that secures the Roller (5D) in place. Then remove the two Rollers.

WELDING WIRE

ROLLERS (5D)

FLIP 180°

FIGURE F

5.Flip each Roller 180 degrees. (See Figure F.)

Note: The two Rollers are “keyed”, which means they can only be reinstalled one way.

6.Reinstall the two Rollers and secure the Rollers in place with the Screw.

(See Figure F.)

7.Install the Spool of Welding Wire and route the Wire to the Torch Gun. Then, test and, if necessary, adjust the Wire Feed Assembly as discussed in the previous pages of this manual.

Attaching the Ground Cable with Clamp

Insert the Connecting Plug to the Ground Cable (22A) into the Terminal Ground (7C) and twist the Connecting Plug to lock in place. (See Parts List on Page 31).

Attaching the Electrode Cable (Arc Welder Only)

Insert the Connecting Plug to the Ground Cable (22A) into the Terminal Electrode (6C) and twist the Connecting Plug to lock in place. (See Parts List on Page 31).

SKU 95424, 95629

For technical questions, please call 1-800-444-3353;

Page 17

Troubleshooting section at end of manual.

 

 

Page 17
Image 17
Chicago Electric 95424, 95629 manual Changing Wire Settings, Attaching the Ground Cable with Clamp, See Figure F