Setting

Display

This function decides whether to display On-Screen Displays. On . . . . .shows all the On-Screen Displays.

Off . . . . .sets On-Screen Displays disappeared except;

On-Screen Menu

“Power off?” message

P-TIMER

“No signal” message

“Please wait...” message

“Searching...” message

Input search

With this function “On”, the projector automatically starts input signal search from Input 1 to Input 5 when turning on the projector. This automatic search stops at the Input where the projector detects any input signal connected.

Note:

When the last selected input source in the Input menu differs from the detected input source, the projector may not display the image properly.

Power management

For reducing power consumption as well as maintaining the lamp life, the Power Management function starts the count down when the input signal is interrupted and no button is pressed for 30 seconds or more.

If the input signal is interrupted and no button is pressed for 30 seconds or more, the timer display with the message “No signal” appears on the screen. The count-down of the set time gets started. The count-down time can be set between 1 and 60 minutes.

When the count-down time has been elapsed, the lamp is turned off to cool itself down. The LAMP indicator dims during this cooling-off period. The next operation depends on the setting as follows :

Ready . . . . . .When the lamp has been fully cooled down, the READY indicator changes to green blinking. In this condition, the projection lamp is turned on if the input signal is reconnected or any button on the top control or remote control unit is pressed.

Shut down . . .When the lamp has been fully cooled down, the power is turned off.

Off . . . . . . . . .The Power Management function is canceled.

On start

When this function is “On,” the projector is automatically turned on just by switching MAIN ON/OFF SWITCH on.

Note:

Be sure to turn the projector off properly (see “Turning Off the Projector” on page 28). If the projector is turned off in the wrong steps, the On start function does not operate properly.

Power management

Time left until Lamp off

Press the SELECT button at Power management and this box appears. Choose “Off” to disable the timer setting, “Ready” or “Shutdown” to enable the timer setting.

Timer Setting

Move the pointer to the timer and set time with the Point buttons (e and d) or the Control pad and press the SELECT button. The timer window disappears and then choose “Ready” or “Shutdown” to enable the timer setting.

52