Appendix A.2

DEFAULT CONFIGURATION PARAM-

ETERS

The configuration parameters can be loaded with
predetermined default values. These data are the
typical values loaded in the instrument prior to
shipment from factory. To load the default values
proceed as follows:
a) The internal switch (V101, see fig. 13) should
be open.
b) The upper display will show:
c) Push the t pushbutton; the display will show
the firmware version.
d) Maintaining the pressure on the t pushbutton
push the s pushbutton also.
The instrument will show:
e) Press s pushbutton to select between table 1
(European) or table 2 (American) default set
of parameters; the display will show:
f) Press FUNC pushbutton; the display will show:
This means that the loading procedure has been
initiated. After about 3 seconds the loading
procedure is terminated and the instrument
reverts to visualization as in point b).
PARA. TABLE 1 TABLE 2
SEr 1 ErO ER0
SEr 2 1 1
SEr 3 19200 19200
SEr 4 7E 7E
P1 3 21
P2 ----. ----.
P3 0 0
P4 400 1000
P5 rEV rEV
P6 0-20 0-20
P7 0 0
P8 400 1000
P9 nonE nonE
P10 H.A. H.A.
P11 nonE nonE
P12 H.A. H.A.
P13 OPrt. OPrt
P14 0 0
P15 0.1 0.1
P16 0 0
P17 0 0
P18 norL norL
P19 norL norL
P20 norL norL
P21 norL norL
P22 Air Air
P23 OFF OFF
P24 rEV rEV
P25 OFF OFF
P26 rEV rEV
P27 OFF OFF
P28 0 0
C O n FC O n F

A. 0 0

O F F
d F L t
t b. 1
d F L t
L O A d
1604-7-A-AB.p65 5/16/00, 10:50 AM2