DEFAULT CONFIGURATION PARAM- ETERS

The configuration parameters can be loaded with predetermined default values. These data are the typical values loaded in the instrument prior to shipment from factory. To load the default values proceed as follows:

a)The internal switch (V101, see fig. 13) should be open.

b)The upper display will show:

C O n F

c)Push the t pushbutton; the display will show the firmware version.

C O n F

A. 0 0

d)Maintaining the pressure on the t pushbutton push the s pushbutton also.

The instrument will show:

O F F

d F L t

e)Press s pushbutton to select between table 1 (European) or table 2 (American) default set of parameters; the display will show:

t b. 1

d F L t

f) Press FUNC pushbutton; the display will show:

L O A d

This means that the loading procedure has been initiated. After about 3 seconds the loading procedure is terminated and the instrument reverts to visualization as in point b).

PARA.

TABLE 1

TABLE 2

SEr 1

ErO

ER0

SEr 2

1

1

SEr 3

19200

19200

SEr 4

7E

7E

P1

3

21

P2

----.

----.

P3

0

0

P4

400

1000

P5

rEV

rEV

P6

0-20

0-20

P7

0

0

P8

400

1000

P9

nonE

nonE

P10

H.A.

H.A.

P11

nonE

nonE

P12

H.A.

H.A.

P13

OPrt.

OPrt

P14

0

0

P15

0.1

0.1

P16

0

0

P17

0

0

P18

norL

norL

P19

norL

norL

P20

norL

norL

P21

norL

norL

P22

Air

Air

P23

OFF

OFF

P24

rEV

rEV

P25

OFF

OFF

P26

rEV

rEV

P27

OFF

OFF

P28

0

0

Appendix A.2

1604-7-A-AB.p65

2

5/16/00, 10:50 AM

Page 36
Image 36
Chromalox 1604-7 user manual Para, ER0