RTD INPUT

RTD

8 9 10

RTD

8 9 10

LINEAR INPUT

 

 

10

+

mA,

 

 

mV

 

_

or

9

V

 

 

 

Shield

10

+

mA

 

 

 

_

mV

9

or

 

 

 

V

Fig. 5 RTD INPUT WIRING

NOTE:

1)Don’t run input wires together with power cables.

2)Pay attention to the line resistance; a high line resistance may cause measurement errors.

3)When shielded cable is used, it should be grounded at one side only to avoid ground loop currents.

4)The resistance of the 3 wires must be the same.

G

Fig. 6 mA, mV AND V INPUTS WIRING

NOTE:

1)Don’t run input wires together with power cables.

2)Pay attention to the line resistance; a high line resistance may cause measurement errors.

3)When shielded cable is used, it should be grounded at one side only to avoid ground loop currents.

4)The input impedance is equal to: < 5 W for 20 mA input

>1 MW for 60 mV input

>200 kW for 5 V input

>400 kW for 10 V input

4

1604-7-1-AB.p65

4

5/16/00, 10:50 AM