Cisco Systems H.323 manual Example, 14presents important static system data parameters

Models: H.323

1 199
Download 199 pages 45.03 Kb
Page 59
Image 59

Chapter 3 Provisioning the Cisco HSI

H.323 Stack Configuration

Table 3-13 Common Call Control Parameters (continued)

Parameter Name

Parameter Value

Description

 

 

 

A_CC_Interworking

0—No interworking encountered (SS7 all

Backward call indicator, Interworking indicator

 

the way)

 

 

1—Interworking encountered

 

 

 

 

A_CC_Location

1—User

Cause indicator, Location

 

2—Private local

 

 

3—Public local

 

 

4—Transit

 

 

5—Public remote

 

 

6—Private remote

 

 

7—International

 

 

8—Interworking

 

 

9—Local interface

 

 

11—Local remote

 

 

12—Packet manager

 

 

13—Unknown

 

 

 

 

The following MML command example shows the command sequence used to provision the call control parameters provided in the preceding table.

Example

mml

>prov-sta::srcver=active, dstver=myconf

>prov-ed:name=CCPackage, A_CC_ANumDataSI=2

>prov-cpy

>restart-softw

Table 3-14presents important static system data parameters.

 

 

Cisco H.323 Signaling Interface User Guide

 

 

 

 

 

 

OL-4806-01 Rev. A14

 

 

3-19

 

 

 

 

 

Page 59
Image 59
Cisco Systems H.323 manual Example, 14presents important static system data parameters