Cisco IE 3010 Switch Getting Started Guide

Relative humidity around the switch does not exceed 95 percent (noncondensing).

Altitude at the installation site is not higher than 10,000 feet.

For 10/100 and 10/100/1000 fixed ports, cable lengths from the switch to connected devices are not longer than 328 feet (100 meters).

For cable lengths for small form-factor pluggable (SFP)-module connections, see the hardware installation guide on Cisco.com and the module documentation.

Installation Warning Statements

This section includes the basic installation warning statements. Translations of these warning statements appear in the Regulatory Compliance and Safety Information for the Cisco IE 3010 Switch document that is on the documentation CD.

Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of:

140°F (60°C) Statement 1047

Warning This equipment is intended to be grounded to comply with emission and immunity requirements. Ensure that the switch functional ground lug is connected to earth ground during normal use. Statement 1064

 

Cisco IE 3010 Switch Getting Started Guide

12

78-19582-02

Page 12
Image 12
Cisco Systems IE301016S8PC manual Installation Warning Statements, 140F 60C Statement