Equipment That You Supply

Chapter 2 Switch Installation

Powering the Switch

Temperature around the unit does not exceed 113°F (45°C).

If the switch is installed in a closed environment or in a multirack assembly, the temperature around it might be greater than normal room temperature.

Humidity around the switch must not exceed 95 percent.

Altitude at the installation site must not be greater than 10,000 feet (3,049 meters).

Do not place any items on the top of the switch.

Do not wall-mount the switch with its front panel facing up. Following safety regulations, wall-mount the switch with its front panel facing down or to the side to prevent airflow restriction and to provide easier access to the cables.

Clearance to the switch front and rear panels meets these conditions:

You can easily read the front-panel LEDs.

Access to ports is sufficient for unrestricted cabling.

The AC power cord can reach from the AC power outlet to the connector on the switch rear panel.

For 10/100 and 10/100/1000 fixed ports, cable lengths from the switch to connected devices are not more than 328 feet (100 meters).

For cable lengths for small form-factor pluggable (SFP)-module connections, see the “SFP Module Connectors” section on page B-2and the module documentation.

Equipment That You Supply

You might need this equipment to install the switch:

Number-2 Phillips screwdriver

Drill with a #27 drill bit (0.144-inch [3.7 mm])

Box Contents

The switch getting started guide on Cisco.com describes the box contents. If any item is missing or damaged, contact your Cisco representative or reseller for support.

Powering the Switch

Before installing the switch in a rack, on a desk, a shelf, or a wall, you should power on the switch and verify that it passes POST.

Power the switch:

Catalyst 2960CPD-8PT-L and 2960CPD-8TT-L

Connect a 10/100/1000 uplink port to a PoE or PoE+ switch, such as a Catalyst 3750-X. Or

Plug the auxiliary power adapter cord into the switch AUX power connector and into an AC power outlet.

Catalyst 3560-C and 2960-C Switch Hardware Installation Guide

2-4

OL-23803-02

 

 