Cisco Systems N55M4Q manual Installation Guidelines

Models: N55M4Q

1 36
Download 36 pages 49.44 Kb
Page 3
Image 3
Warning No user-serviceable parts inside. Do not open. Statement 1073

Chapter 2 Switch Installation

Preparing for Installation

Warning For connections outside the building where the equipment is installed, the following ports must be connected through an approved network termination unit with integral circuit protection: 10/100/1000 Ethernet. Statement 1044

Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: 113°F (45°C)

Statement 1047

Note For Catalyst 3560CG-8PC-S, 3560CG-8TC-S, and 2960CG-8TC-L switches, the maximum recommended ambient temperature is: 104°F (40°C).

Warning No user-serviceable parts inside. Do not open. Statement 1073

Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074

Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm) Statement 1076

Warning Hot surface. Statement 1079

Note Applies to the Catalyst 3560CG-8PC-S switch.

Installation Guidelines

Before installing the switch, these guidelines must be met:

The operating environment must be within the ranges listed in Appendix A, “Technical Specifications.”

Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures. Make sure that the cabling is away from other devices that might damage the cables.

Airflow around the switch and through the vents must be unrestricted. We strongly recommend that you allow at least 3 in. (7.6 cm) of clearance from the left, right, and top sides of the switch to avoid any flow blockage. If you are installing the switch in a rack, allow at least 1.75 in.

(4 cm) of empty rack space above each switch.

Catalyst 3560CG-8PC-S, 2960C-8PC-L, 2960C-12PC-L, 3560C-8PC-S, and 3560C-12PC-S switches: Allow at least 1.75 in. (4 cm) clearance from the ends of the external heat sink fins.

Catalyst 3560-C and 2960-C Switch Hardware Installation Guide

 

OL-23803-02

2-3

 

 

 