Chapter 5 Installing Memory in the Router

Replacing Flash Memory SIMMs

Figure 5-17 Removing Flash Memory SIMMs

Top view

1. Pull the locking spring clips outward.

2. Push the top of the SIMM forward and down.

Front of chassis

SIMM polarization notch

H7085

Installing Flash Memory SIMMs

Perform this procedure to install Flash memory SIMMs:

Step 1 Locate the Flash memory SIMM sockets on the mainboard. (See Figure 5-14through Figure 5-16.)

Caution Handle SIMMs by the non-connector edges only. SIMMs are ESD-sensitive components and can be damaged by mishandling.

Step 2 Hold the SIMM with the polarization notch on the right and the component side away from you, with the connector edge at the bottom.

Step 3 Beginning with bank 0, insert the Flash memory SIMM into its connector slot at an angle, tilted toward the left side of the chassis. (See Figure 5-18.) Rock the SIMM into a vertical position using the minimum amount of force required. When the SIMM is properly seated, the socket guide posts fit in the alignment holes, and the locking springs click into place. Use a minimum of force.

Cisco 3600 Series Hardware Installation Guide

 

OL-2056-02

5-23

 

 

 