3Printer Adjustments

Installing the Media (p.25, p27)

Sensor Adjustments and Calibration

The sensing level of both the transparent (see thru) and reflective sensors is adjusted separately and independently. Firstly, the sensor type must be selected using the Sensor Method Selection shown below. Then the adjustment and calibration of the sensor can be made.

The front sensor or adjustable sensor is selected using the Adjustable sensor on the sub menu that is in Page Setup on the main menu. (See “Chapter 2. Printer Operation”). The adjustable rear sensor is set by Factory Default.

Entering Sensor Adjustment Mode

1.Turn on the power while pushing the PAUSE key, FEED key, and STOP key simultaneously.

PAUSEFEEDSTOP

Power Switch

2.After “Sensor Cal Mode” lights up, release the keys to change the printer to sensor adjustment setting mode.

Sensor Cal Mode

See Through

POWER ERROR

Quick Sensor Selection Method

(Transparent Reflective)

To switch from transparent to reflective sensor, hold down the MENU key and then press the STOP key. Each time you press the STOP key, you switch to back and forth between the two sensor types.

If the transparent sensor is selected, “See Through” is displayed and the buzzer sounds once. If the reflective sensor is selected, “Reflect” is displayed and the buzzer sounds twice.

STOP

Sensor Cal Mode

ReflectMENU

Hold Press/Release

POWER ERROR

54