Printer Adjustments

Sensor Adjustments and Calibration

Adjusting the Transparent sensor

1.The transparent sensor is selected.

2.Install only the liner media (label backing paper) with the label media removed so that it will pass between the platen roller and the media sensor. (Be careful that media with black marks does not pass the media sensor.) Then close the sensor arm and the printhead.

Upper sensor

Label

Media gap

Liner media

Bottom sensor

3.If the Pause Key is pressed then released while the MENU key is continually pressed, the sensor is automatically adjusted.

PAUSE

Sensor Cal Mode

Executing

MENU

Hold Press/Release

4.When automatic adjustment stops normally, “Succeeded” is displayed by the LCD. If it stops abnormally (adjustment is impossible), ERROR LED flashes and “Failed” is displayed on the LCD.

Sensor Cal Mode

Succeeded

5.If the STOP key is pressed, the Printer completes sensor adjustment and the printer restarts.

55