Printer Adjustments
Sensor Adjustments and Calibration
Adjusting the Transparent sensor
1.The transparent sensor is selected.
2.Install only the liner media (label backing paper) with the label media removed so that it will pass between the platen roller and the media sensor. (Be careful that media with black marks does not pass the media sensor.) Then close the sensor arm and the printhead.
Upper sensor
Label | Media gap |
Liner media
Bottom sensor
3.If the Pause Key is pressed then released while the MENU key is continually pressed, the sensor is automatically adjusted.
PAUSE
Sensor Cal Mode
Executing
MENU
Hold Press/Release
4.When automatic adjustment stops normally, “Succeeded” is displayed by the LCD. If it stops abnormally (adjustment is impossible), ERROR LED flashes and “Failed” is displayed on the LCD.
Sensor Cal Mode
Succeeded
5.If the STOP key is pressed, the Printer completes sensor adjustment and the printer restarts.
55