3Printer Adjustments

Sensor Adjustments and Calibration

Adjusting the Reflective sensor

1.The reflective sensor is selected.

2.With the reflective sensor selected, install the label media so that it is between the platen roller and the media sensor.

Be careful that black mark and media gap do not pass the media sensor. Then close the sensor arm and the printhead.

Label

Black mark

Liner media

Bottom sensor

3.If the Pause Key is pressed then released while the MENU key is continually pressed, the sensor is automatically adjusted.

Sensor Cal Mode

Executing

4.When automatic adjustment stops normally, “Succeeded” is displayed by the LCD. If it stops abnormally (adjustment is impossible), ERROR LED flashes and “Failed” is displayed on the LCD.

Sensor Cal Mode

Succeeded

5.If the Cancel (STOP) key is pressed, the Printer completes sensor adjustment and the printer restarts.

56