4.9Connecting the PHU (Paper Holding Unit)
1.Turn off the power.
2.Plug the connector cable of the optional PHU into the CN5 on the control PCB. When plugging it, pay attention to its insertion direction.
Connector for PHU
CN5
4.10Paper Near End Function (When Using the PHU)
If the paper is running out, the PNE sensor informs the host computer that the paper is running out. You can adjust the printable amount left after PNE has been detected, up to aboutφ50 of paper roll.
1.Loosen the screw and slide the PNE sensor position forward or backward. When you slide the PNE sensor away from the paper roller, the printable amount left after PNE has been detected will be increased.
2.When replacing the paper, replace it according to the procedure in "4.3 Inserting the Paper."
Screw
PNE
Sensor
22 | CITIZEN |