PPU-231 User’s Manual

5.2DIP Switch Function

DIP switch 1 (DS1)

 

No.

Function

 

 

 

ON

 

 

OFF

 

Upon Shipment

 

DS1- 1

Auto cutter

 

 

 

Enabled

 

Disabled

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

CR switching

 

LF operation

 

Ignored

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Printing density

 

 

Combination with DS2-6.

 

OFF

 

 

 

 

See Table 2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

DTR-DSR/XON-XOFF

 

XONXOFF

 

DTRDSR

 

OFF

 

5

 

Baud rate and parity setting

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Baud rate and parity setting

 

 

See Table 1.

 

OFF

 

 

 

 

 

 

 

 

 

 

 

7

 

Baud rate and parity setting

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Baud rate and parity setting

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch 2 (DS2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

Function

 

ON

 

OFF

 

Upon Shipment

 

 

1

 

PNE function

 

Enabled

 

Disabled

 

ON•

 

 

2

 

Reserved

 

 

 

 

 

 

 

ON

 

 

3

 

Reserved

 

 

 

 

 

 

 

ON

 

 

4

 

Auto-loading

 

Enabled

 

Disabled

 

ON

 

 

5

 

Paper selection

 

Normal thermal

 

Dedicated

 

ON

 

 

 

 

 

 

paper

 

thermal paper

 

 

 

 

 

 

 

 

 

 

(Black mark)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Print density

 

Combination

with DS1-3.

 

ON

 

 

 

 

 

 

See Table 2.

 

 

 

 

 

7

 

Data length

 

8 Bits

 

7 Bits

 

ON

 

 

8

 

Not used

 

 

 

 

 

 

 

ON

 

* With the type U model (North American type), the DIP switches marked are set to OFF.

Table 1 Baud rate and parity setting

DS1-8

DS1-7

DS1-6

DS1-5

Interface

Parity

Baud Rate

 

 

 

 

 

 

 

OFF

OFF

OFF

OFF

Parallel input

OFF

OFF

OFF

ON

Serial input

None

1,200 bps

OFF

OFF

ON

OFF

2,400 bps

OFF

OFF

ON

ON

4,800 bps

OFF

ON

OFF

OFF

9,600 bps

OFF

ON

OFF

ON

19,200 bps

OFF

ON

ON

OFF

Odd

1,200 bps

OFF

ON

ON

ON

2,400 bps

ON

OFF

OFF

OFF

4,800 bps

ON

OFF

OFF

ON

9,600 bps

ON

OFF

ON

OFF

19,200 bps

ON

OFF

ON

ON

Even

1,200 bps

ON

ON

OFF

OFF

2,400 bps

ON

ON

OFF

ON

4,800 bps

ON

ON

ON

OFF

9,600 bps

ON

ON

ON

ON

19,200 bps

25

CITIZEN

Page 38
Image 38