PPU-231 User’s Manual

ESC c 5

n

 

 

 

 

[Function]

 

Enabling/Disabling Panel Switches

[Code]

 

<1B>H<63>H<35>H<n>

[Range]

 

{0 ≤ n ≤ FF}

Data is described in Hex code.

[Outline]

Selecting the LF switch valid/invalid.

 

 

• "n" is valid only in the lowest bit (n0).

 

 

• "n" bit means the followings.

 

 

 

 

 

 

 

 

n0

 

Condition

 

 

 

0

 

LFSW valid.

 

 

 

1

 

LFSW invalid.

 

[Caution]

When the panel switch is disabled with this command, the LF switch is disabled.

 

 

Therefore, the paper cannot be fed by operating the LF switch.

[Default]

• The initial value of n is "0".

[Sample Program]

 

 

 

 

 

 

LPRINT CHR$ (&H1B) + "c5" + CHR$ (0) ; ………… When enabling the LF switch

 

 

LPRINT CHR$ (&H1B) + "c5" + CHR$ (1) ; ………… When disabling the LF switch

ESC d

n

[Function]

Printing and Feeding the paper by n lines

[Code]

<1B>H<64>H<n>

[Range]

* {0 ≤ n ≤ FF} Data is described in Hex code.

[Outline]

Prints data inside the buffer and feeds paper by n lines.

 

• Specified line does not remain.

 

• The beginning of the line is to be considered as the next printing start position.

[Default]

• The initial value is not defined.

[Sample Program]

LPRINT "AAAAA"

LPRINT CHR$ (&H1B) + "d" + CHR$ (2) ;

LPRINT "AAAAA" + CHR$ (&HA) ;

[Print Results]

60

CITIZEN

Page 73
Image 73