PPU-231 User’s Manual

GS ^ n1 n2 n3

[Function]

Executing the Macro

 

 

[Code]

<1D>H<5E>H<n1><n2><n3>

[Range]

{0 ≤ n1 ≤ FF}

 

 

 

{0 ≤ n2 ≤ FF}

 

 

 

{0 ≤ n3 ≤ 1} Data is described in Hex code.

[Outline]

Executing contents defined in macro.

 

• "n1∼n3" indicate as follows:

 

n1 : The number of times of macro execution

 

n2 : Waiting time on macro execution

 

 

Waiting time of n2 x 100 msec is given for every execution.

 

n3 : Macro execution mode

 

 

 

 

 

 

 

 

n3

 

Mode

 

 

 

0

 

Continuous execution

 

 

 

1

 

Execution by LFSW

 

 

Continuous execution:

The Macro is executed n1 times continuously at the time

 

 

 

 

intervals specified by n2.

 

Execution by FEED S:

After waiting for lapse of time specified by n2, the

 

 

 

 

ALAME LED flickers and the LF switch is waited to be

 

 

 

 

pressed. When it is pressed, the macro is executed once.

 

 

 

 

This action is repeated n1 times.

[Caution]

• When this command is received while in macro definition, suspension of macro

 

 

definition is indicated. At this time, the defined content is cleared.

 

• No execution takes place when macro is held undefined or n1=0.

 

• While in macro execution with n3=1, paper feed with the LF SW is not available.

[Default]

• Initially, this command is not specified.

[See Also]

GS :

 

 

[Sample Program]

 

 

 

[Print Results]

See Sample Program and Print Results for GS : on Page 79.

80

CITIZEN

Page 93
Image 93
Citizen PPU-231 manual GS n1 n2 n3