- 152 -

2.2.16 Printer Function Setting Commands

GS ( D pL pH m [a1 b1]...[ak bk]
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 CT-S310
support model PMU2XXX
[Function] Enabling or disabling real-time command
[Code] <1D>H<28>H<44>H<pL>< pH>< m> [<a1>< b1>]…[<ak>< bk>]
[Range] 3(pL+pH×256)65535
m20
a1
b014849
[Outline] [The specification which is common to the model]
Enables/disables the following real-time command processing.
Function a b
048 Does not process DLE DC4 fn m t (fn = 1). (Invalid)
1 149 Processes DLE DC4 fn m t (fn = 1). (Valid)
• pL and pH sets the number of bytes on and after m in (pL + pH x256).
• “a” sets the kind of real-time command.
• “b” sets Valid or Invalid.
• When data raw that meets the code configuring real-time command in the image data, it is
recommended that the real-time command be set to invalid by this command.
[Default]
Type of Real-time Command Initial Value
a
DLE DC4 fn m t (fn=1): Real-time output of pulse specified Valid
1