- 277 -
MSW1-3Busy condition
[Outline] Select the condition that printer is BUSY. Automatic status send function also runs.
OFF(0) ON(1)
Busy Condition Buffer full/Off-line Buffer full
ON (1) OPERATION: If receive buffer is full, printer is BUSY.
Automatic status send ASB function is enabled.
OFF (0) OPERATION: If receive buffer is full or off-line, printer is BUSY.
Automatic status send ASB function is disabled.
[Additional Description]
Even if ON is selected, printer enters BUSY status when power is turned on or reset by I/F or at self
test print
Printer Status MSW1-3
OFF
MSW1-3
ON
Power-up or reset used by I/F
Self-print
Cover open
Paper-feed by FEED SW
Paper-end (including print stop in PNE)
Error generation
Off-line
Waiting during macro run by FEED SW
Buffer full Receive buffer full
MSW1-4 Receive error character
[Outline] Select handling of data detected where the serial comm unication detects the receive data framing
error, overrun error and parity error.
OFF(0) ON(1)
Receive Error Print ? No Print
ON (1) OPERATION: Not printed as “?”
OFF (0) OPERATION: Printed as “?”