- 206 -
initialization to be valid o
fn=351 Function 3 Specifies the auto loading function of the set value at
r invalid
GS ( M pL pH fn m
[Code] <1D>H<28>H<4D>H<pL><pH><fn><m>
[Range] (pL+pH×256)=2(pL=2pH=0)
fn=351
m=014849
[Outline] [The specification which depend on the model]
Determines the setting of storage area at initialization to the work area by the value of “m”.
m Function
048 Does not copy data from storage area to work area at initialization.
149 Copies data from storage area to work area at initialization.