- 191 -
PMU2XXX
• a = 5: When print density is specified
Setting Status Sending Data
Stored
Value Print Density 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
65530 70% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 48(“0”)
65531 75% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 49(“1”)
65532 80% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 50(“2”)
65533 85% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 51(“3”)
65534 90% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 52(“4”)
65535 95% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 53(“5”)
0 Basic density 48(“0”)
1 105% 49(“1”)
2 110% 50(“2”)
3 115% 51(“3”)
4 120% 52(“4”)
5 125% 53(“5”)
6 130% 54(“6”)
7 135% 55(“7”)
8 140% 56(“8”)
• a = 6: When printing speed is specified
Setting Status Sending Data
Stored
Value Print Speed 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1 Speed level 1 49(“1”)
2 Speed level 2 50(“2”)
3 Speed level 3 51(“3”)
4 Speed level 4 52(“4”)
5 Speed level 5 53(“5”)
6 Speed level 6 54(“6”)
7 Speed level 7 55(“7”)
8 Speed level 8 56(“8”)
9 Speed level 9 57(“9”)
• a = 201: When ACK output position is specified
Setting Status Sending Data
Stored
Value
ACK Output
Position 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1 ACK-in-Busy 49(“1”)
2 ACK-while-Busy 50(“2”)
3 ACK-after-Busy 51(“3”)
• a = 202: Input buffer full Busy output/cancel timing
Setting Status Sending Data
Stored
Value
BUSY
Output/Cancel 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1 49(“1”)
2 50(“2”)
3 51(“3”)
4 52(“4”)