- 148 -
GS C ; n1 ; n2 ; n3 ; n4 ; n5 ;
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 CT-S310
support model PMU2XXX
[Function] Setting the numbering counter mode (B)
[Code] <1D>H<43>H<3B>H<n1><3B>H<n2><3B>H<n3><3B>H<n4><3B>H<n5><3B>H
<n1>、<n2>、<n3>、<n4>、<n5> are character codes.
[Range] 0n1n2n565535
0n3n4255
[Outline] [The specification which is common to the model]
This command sets the numbering (serial number counter) mode and a counter value.
n1: Counter default
n2: Counter final value
n3: Counter step value
n4: Identical counter print count
n5: Counter start value
n1 < n2: Count-up system
n1 > n2: Count-down system
n1 = n 2 or n3 = 0 or n4 = 0 : Counter stop
[Caution] • If the n5 counter start value is beyond the counter range specified with n1 and n2, it is assumed to
be n1 = n5.
• If each value of n1 through n5 contains the character co de other than “0” through “9”, the printer
will invalidate the data up to that parameter and handle the subsequent data as normal data.
[Default] n1=1n2=65535n3=1n4=1n5=1
[See Also] GS C 0GS C 1GS C 2GS c