5.5TRIGGER SETUP:

There are three Voltage Triggers on the SSP-60. They are used to turn associated equipment on and off.

Trigger setup

Trigger 1 sense Power On

- polarity

Posit.

- delay

No

- duration

Infin.

Trigger 2 sense Power On

- polarity

Posit.

- delay

No

- duration

Infin.

Exit

 

TV Display

These displays show that you have accessed the Trigger setup sub-menu and highlighted Trig1 sense. You can scan through the available choices by pressing the \/ and /\ buttons on the remote. When the selection you wish to adjust is highlighted press the < or > key to scroll through the choices. To leave the menu and save the settings scroll down to Exit and press the ENTER key.

Trigger setup

 

Trig1 sense:

Power On

 

 

Panel Display

 

Trigger 1 controls the TRIGGER 1 voltage output and Trigger 2 controls the TRIGGER 2 and TRIGGER 3 outputs. TRIGGER 2 and TRIGGER 3 always turn On or Off at the same time. Use the \/ and /\ keys to select and use the < and

>keys to cycle through the available choices. The following applies to both Trigger 1 and Trigger 2.

5.5.1Trigger sense selects what event will activate the Trigger output. Set “sense” to Power On to activate the trigger when switching out of STANDBY (and de-activate it when returning to STANDBY). Alternatively the trigger output may be activated when a particular Source is selected.

5.5.2Trigger polarity sets the state of the trigger output. “Posit.” provides a +12V DC output when the trigger is active and no voltage when inactive. “Negat.” sends no voltage output when the trigger is active and +12V when inactive.

5.5.3Trigger delay sets a delay between the “sense” signal and the trigger output voltage changing. The delay may be set to various times from 1 second to 3 minutes or to “No” which gives no delay.

5.5.4Trigger duration sets the period (duration) that the trigger output is active. The trigger duration may be set to various times from 10ms (milliseconds) to 3 minutes, or to “Infin.” which keeps the trigger active while the "sense" condition prevails.

Exit returns to the main menu

24

Page 24
Image 24
Classe Audio SSP-60 owner manual Trigger Setup, Trigger setup Trig1 sense Power On