NOTES ON THE ABOVE TABLE:
NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent
to the switchers, it will reset according to the present power down settings.
NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it performs the instruction, and if
the instruction is performed (due to a keystroke on the front panel), then these codes are sent. For example:
0000 0001
1000 0101
1000 1000
0011
was sent from the PC, then the switcher (machine # 3) will switch input 5 to output 8. If the user switched input # 1 to ou tput
# 7 via the front panel keypad, then the switcher will send:
0100 0001
1000 0001
1000 0111
1000 0011 to the PC.
When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by
sending to the PC the same four bytes that it sent (except for the first byte, where the DESTINATION bit is set "high") .
NOTE 3 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are
returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per
the definitions in instructions 7 and 8 respectively. For example, if the present status of machine number # 5 is breakaway
setting, then the reply to
0000 1011 0100 1100
1000 0001 Would be 1000 0001
1000 0000 1000 0001
1000 0101 1000 0101
NOTE 4-The reply to the "REQUEST WHETHER SETUP IS DEFINED" is as in TYPE 3 above, except that here the
OUTPUT is assigned with the value 0 if the setup is not defined; or 1 if it is defined.
NOTE 5-An error code is returned to the PC if an invalid code was sent to the switcher (e.g. trying to save to a setup gr eater
than 8, or trying to switch an input or output greater than the highest one defined) . This code is also returned to the PC if an
RS-232 instruction is sent while the machine is being programmed via the front panel. Reception of this code by the switcher
is not valid.
NOTE 6–This code is reserved for internal use.
NOTE 7-SETUP #0 is the present setting. SETUP #1 to SETUP# 8 are the settings saved in the switcher's memory, (i.e.
those used for Store and Recall).
NOTE 8-Under normal conditions, the machine's present status is saved each time a change is made. The "power-down"
save (auto-save) may be disabled using this code. Note that whenever the machine is turned on, auto-save function is set.
NOTE 9–This is identical to instruction 3 (machine uses instruction 3, when sending to PC).
NOTE 10–This is identical to instruction 4 (machine uses instruction 4, when sending to PC).
NOTE 11-This is a request to identify the switcher/s in the system. If the INPUT is set as 1 or 2, the machine will send its
name. The reply is the decimal value of the INPUT and OUTPUT. For example, the reply to the request to send machine
name (for machine number 001) would be:
0111 1101
1000 1000 (i.e. 128 + 8)
1000 1000 (i.e. 128 + 8)
1000 0001
If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version
number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in
front of the decimal point, and the OUTPUT representing the number after it.
For example, for version 3.5, the reply would be:
0111 1101
1000 0011 (i.e. 128 + 3)
1000 0101 (i.e. 128 + 5)
1000 0001