| Ice Frost Operator’s Manual |
Problem |
| Possible Cause |
| Solution |
Cap is leaking | • | The nut is loose | • | Tighten the nut |
Bowl not refilling | • | Out of syrup | • | Replace |
| • | Out of CO2 | • | Replace |
| • Valves are shut off or blocked | • | Open | |
| • | Foam covering probes | • | Wait |
| • Fill Switch in off position | • | Turn on | |
| • Defective syrup pressure switch | • | Replace | |
| • Defective CO2 shut off | • | Replace | |
Bowl is overfilling | • | Bad Pressure and Levels Card | • | Replace the card |
CO2 leaking from back of unit | • | Proper function of bowl over | • If not continuous leak it is nor- | |
|
| pressure discharge solenoids |
| mal operation |
| • | Poor connection | • | Repair leak |
WARNING: Relief valve venting is normal, a continuous leak is not and must be corrected immedi- ately. Repair the solenoid valve.