2-9. Installing Wire Spool And Adjusting Hub Tension

Use compression spring with 8 in (200 mm) spools.

Tools Needed:

15/16 in

When a slight force is needed

to turn spool, tension is set.

ST-072573-B

2-10. Changing Input Voltage

2

3

1

4

YTurn Off unit, and disconnect input power.

Unit was shipped from factory set for 230 volts.

1Transformer T1

2Rear Of Power Switch S1

3Lead Marked 230 Volt And Fan Motor Lead

Disconnect 230 volt lead and fan motor lead from rear of S1. Leave fan motor lead connected to 230 volt lead.

4 Lead Marked 200 Volt

Remove cable tie, and slide short piece of sleeving off 200 volt lead, and slide sleeving over end of 230 volt and fan motor leads. Fold sleeving over and secure in place.

Connect 200 volt lead to S1 where 230 volt lead was removed.

Reinstall wrapper.

Tools Needed:

3/8, 7/16 in

ST-801 580-A

OM-194 199 Page 9