TO ADJUST QUICK-STOP

The quick-stop is preset at the factory to stop the miter fence at exactly zero degrees. However, when sliding miter table adjustments are made, these adjustments may cause the quick stop to need adjusting. Check quick-stop with miter scale set at

zero degrees. If adjustments are needed, proceed with the following steps:

Loosen the eccentric screw holding the quick-stop.

Place the quick-stop against the miter fence with miter scale set at zero degrees. See Figure 60.

Adjust eccentric screw until it holds quick-stop securely against miter fence.

Retighten hex nut, securing eccentric screw and quick-stop.

Check your work. If the quick-stop is not at zero degrees, repeat steps 1-4.

M_ERINDICATOR

 

MITER FENCE

ZERO

ADJUSTING CLAMP

DEGREE

 

MITER

FENCE

QUICK STOP AND

 

ECCENTRIC SCREW

Figure 60

41

CRAFTSMAN" TABLE SAW 315.228110

Page 41
Image 41
Craftsman 315.22811 To Adjust QUICK-STOP, Merindicator Miter Fence Zero, Degree, Quick Stop Eccentric Screw