© 2007 Cypress Solutions
Installation and Operation Manual: CTM-130 / CTM-132 (Revision 1.2)
Page - 37 -

11 Technical Specifications

The Chameleon range of wireless data modems are subject to regular feature enhancement. Cellular

wireless networks are constantly changing and enhancing their capabilities. In order to meet these

changing needs, Cypress Solutions Inc. reserves the right to modify these product specifications without

notice.

______________________________________________________________________________________________

Approvals

EMC FCC part 15 Class A; ICES-003 Class A
Mobile device FCC CFR 47 part 2.1091; Industry Canada RSS-102
______________________________________________________________________________________________

Temperature

Operating MIL-STD 810F Method 502-II, -30 to +65 Celsius
Storage SAE 1455 4.2.3, -40 to +75 Celsius
______________________________________________________________________________________________

Humidity

5 to 95%RH SAE 1455 4.2.3, 85-95% RH for two 24hr cycles
______________________________________________________________________________________________

Vibration

5 to 500Hz MIL-STD 810F Method 514.5C
______________________________________________________________________________________________

Shock

40G, 11msec MIL-STD 810F Method 516-I
______________________________________________________________________________________________

Sealing

IP53 Protection against dust and spray water
______________________________________________________________________________________________

Material

Case 6061 High strength Aluminum
Base Oil & Solvent resistant automotive grade Santoprene
______________________________________________________________________________________________

Power Supply

Voltage 9 to 36 VDC
Current Operation 200mA typical, 300mA max at 12VDC
Standby 15mA typical at 12VDC
<1mA shutdown mode
Protection SAE J1455
______________________________________________________________________________________________

Serial port

Connector DB9, RS232C, DCE configuration
Protocols AT commands, PPP/SLIP, PAD, MODBUS RTU/ASCII, SMTP
______________________________________________________________________________________________

I/O

Outputs 4 Digital outputs, open drain configuration
500mA sink capability, overload protection
Inputs 6 Digital or Analog inputs
2.5V +/- 0.5V digital detection threshold, 36VDC withstand
0 to 10V analog range, 10mV resolution, +/- 50mV accuracy
______________________________________________________________________________________________

RF

800MHz & SMA 50ohm connector
1,900MHz bands +23.5dBm max
______________________________________________________________________________________________

GPS (CTM-132)

Type 8 channel, continuos tracking
Accuracy <6 metres typical
Acquisition Cold start <2mins typ.; Warm start <45secs typ.; Reacquisition <2secs typ
______________________________________________________________________________________________