In the following table, the software controlled STORE and RECALL cycle parameters are listed.[24, 25]

Parameters

Description

 

20 ns

 

25 ns

 

45 ns

Unit

Min

 

Max

Min

 

Max

Min

 

Max

 

 

 

 

 

 

tRC

STORE/RECALL Initiation Cycle Time

20

 

 

25

 

 

45

 

 

ns

tSA

Address Setup Time

0

 

 

0

 

 

0

 

 

ns

tCW

Clock Pulse Width

15

 

 

20

 

 

30

 

 

ns

tHA

Address Hold Time

0

 

 

0

 

 

0

 

 

ns

tRECALL

RECALL Duration

 

 

200

 

 

200

 

 

200

μs

Switching Waveforms

Figure 12. CE and OE Controlled Software STORE/RECALL Cycle[25]

 

 

W5&

W5&

 

$GGUHVV

 

$GGUHVV

$GGUHVV

 

 

W6$

W&:

W&:

 

 

 

 

&(

 

W+$

W+$

 

W

 

 

6$

W+$

W

 

 

 

 

 

 

 

 

 

+$

2(

 

 

 

 

 

 

 

 

W+++'

+6% 6725(RQO\

W/=&(

W+=&(

W'(/$<

W/=+6%

 

 

'4 '$7$

 

 

 

+LJK,PSHGDQFH

 

 

 

W6725(W5(&$//

 

 

 

 

5:,

 

 

 

 

Figure 13. AutoStore Enable/Disable Cycle

 

W5&

W5&

$GGUHVV

$GGUHVV

$GGUHVV

W6$

W&:

W&:

 

&(

W+$

W+$

W6$

W+$

 

W

 

 

+$

2(

 

 

 

W+=&(

W66

W/=&(

W

 

 

'(/$<

'4 '$7$

 

 

5:,

 

 

Notes

24.The software sequence is clocked with CE controlled or OE controlled reads.

25.The six consecutive addresses must be read in the order listed in Table 1 on page 5. WE must be HIGH during all six consecutive cycles.