TO START … con’t

OPERATING INSTRUCTIONS

TO START … con’t

After Pushing the START touch pad:

The appliance will automatically start in the #1 or low feed rate, no matter where you set it.

When the FEED RATE LED is flashing FAST, this indicates the unit has not reached 120° F exhaust temperature.

When the FEED RATE LED flashes at a SLOWER rate, this indicates the control has reached the 120°F temperature and as entered a 5 minute “Safety Delay”

When the 5 minute “Safety Delay” is complete the IGNITER LED and igniter will turn off and the FEED RATE LED will become solid, meaning you are now in control.

TO ADJUST HEAT

Simply press the START/FEED RATE touch pad to adjust heat output.

Note: During start-up you may adjust the feed rate. This setting will take affect once the Start-up sequence is complete.

TO SHUT DOWN

Press the OFF pad.

OPERATING IN THERMOSTAT HIGH / LOW CYCLE (Flashing 3 & 4)

This requires purchasing the optional “Wall Thermostat Add-on Kit”.

This mode of operation is preferred over the ON/OFF mode, during those long and chilly winter nights. The life of the Auto Igniter is greatly increased, and once you have the room to temperature it does not take as much energy to keep it at that temperature.

TO START

Once this mode has been selected, you simply press the START touch pad to

Feed Rates 3 & 4

activate the stove.

TO ADJUST HEAT

 

You can now select the HIGH heat output level (2,3 or 4) by pushing the

 

START / FEED RATE touch pad, you can also select the FAN setting you desire.

 

When you have selected your high level and fan speeds the LED’s will continue

 

to flash. The appliance will automatically start at the #1 feed rate until the Start-

 

up procedure is complete.

 

The LOW (number 1) or selected High (2,3 or 4) Feed Rate indicator light will

 

light up depending on if the thermostat is calling for heat or not. When the

 

desired room temperature is reached the stove will automatically go into the low

 

heat (#1) cycle. When the temperature in the room drops to the level set at the

 

thermostat, the stove will again cycle to the HIGH (#2,3 or 4) preselected set-

 

ting. For optimum heat transfer, the FAN setting should be set at LOW or

 

MEDIUM. The appliance will run the FAN at HIGH speed when needed,

 

automatically.

 

TO SHUT DOWN

 

To turn off the appliance press the OFF touch pad.

 

Glow Boy Home & Shop Heater www.glowboystoves.com 2424