OPERATING IN THERMOSTAT ON / OFF (Flashing 1 & 2)

OPERATING INSTRUCTIONS

OPERATING IN THERMOSTAT ON / OFF (Flashing 1 & 2)

This also requires purchasing the optional “Wall Thermostat Add-on Kit”

Feed Rates 1 & 2

This mode of operation is best suited for those “Take of the Chill” nights of spring, summer , fall.. The thermostat should be set for the desired room temperature. If the room temperature drops below the level on the thermostat the stove will automatically begin the start-up cycle, as explained in the manual operation section.

In this mode the life of the IGNITER is reduced and the power consumption will be higher. If the thermostat calls for heat while the stove is still cooling down, the stove will go through the START-UP cycle.

TO START

Once this mode has been selected, you simply press the START touch pad to Activate the stove. Once the start-up cycle is completed the stove run on the pre-selected “HIGH” (number 2,3 or4) setting, till the temperature is reached.

TO ADJUST HEAT

You can select the HIGH heat output level (2,3 or 4) by pushing the START touch pad, you can also select the FAN setting you desire. The stove will now go through its

normal start up cycle. Once completed the appliance is now in the ON / OFF mode.

For optimum heat transfer, the FAN setting should be set at LOW or MEDIUM. The appliance will run the FAN at HIGH speed when needed, automatically.

TO SHUT DOWN

The thermostat will shut the stove down when the desired room temperature is reached. The Feed Rate num- bers 1 & 2 will flash while the appliance is in the OFF part of this mode to give you a visual indication that the appliance is still active and in the ON / OFF cycle.

HINT: If you find that the stove turns off and on repeatedly, you may wish to turn the FEED RATE to a lower setting. The lower setting will provide a more consistent heat output over time, eliminating the need for the thermostat to repeatedly turn the stove off.

UNDERSTANDING THE CONTROL

TRIM POTS (Fine Tune Adjustments)– Factory Settings

FUEL FEED rates at the Lowest (number 1) and highest (number 4) settings can be adjusted by

Decrease

Increase

adjusting the fine tune trim pots located on the control panel. To raise fuel feed turn trim pot

FINE TUNE ADJUSTMENTS

counter clockwise and to lower turn clockwise. To assist in knowing what the change is you

 

 

 

 

 

should note the amount of time the light on the AUGER CYCLE LED stays OFF. (Note: The light

 

 

 

 

 

stays on when ever the fuel feed motor, AUGER CYCLE, is running). Lengthening the time this

1

 

 

4

 

LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed.

 

 

 

 

 

 

 

 

FAN (Combustion) TRIM; this trim may be used to raise or lower the amount of air moving

 

 

 

FAN

through the burn grate for the cleanest burn, ONLY when the control is on the Low Feed Rate (1),

 

 

 

 

 

and only after the Air Inlet damper has been set during the High Feed Rate (4)..

 

 

 

 

 

Note: If you attempt to adjust the Trim Pots, use a small precision screwdriver.

 

 

 

 

 

The Trim Pots do not make a full rotation. If using a metal screwdriver, be gentle as the

 

 

 

 

 

plastic trim pot slot can be damaged or stripped.

 

FAN SPEED

AUGER CYCLE

 

HI

 

 

 

 

 

 

 

 

The AUGER CYCLE LED indicates when a electrical signal is being sent to the auger motor. It is

MED

AUGER

NOT used to indicate the actual movement of the auger. When the signal is being sent the LED will

be solid for 3 seconds. When the LED is off no signal is being sent.

 

 

 

 

CYCLE

 

LOW

 

 

FAN SPEED (Convection or heating)

 

 

 

 

 

 

 

 

 

The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat

 

 

 

FAN

 

 

 

exchange tubes and back into the room. The FAN SPEED has 5 different speeds, these are con-

 

 

 

SPEED

trolled by pushing the FAN SPEED touch pad. The Low LED will be solid when on the lowest fan

 

 

 

 

 

speed, the LOW & MED will both be solid when the next highest speed is selected and so on.

 

 

 

 

 

 

 

 

OFF

 

.When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa

 

 

 

 

versa.

 

 

 

 

 

 