SPECIFICATIONS
HEATING SPECIFICATIONS
Approx. Heating capacity (sq. feet) * | 800 – 2,000 |
|
|
Approx. Fuel burn rate per hour ** | 1.5 – 5 lbs |
|
|
Hopper Capacity - Home 120 | 120 lbs | Approx. Burn time at lowest setting | 90 hrs |
Hopper Capacity – Home 300 | 300 lbs. | Approx. Burn time at lowest setting | 200 hrs |
¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature. Fuel size, quality, density and moisture level will also have an effect.
¹¹Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.
DIMENSIONS
24” | 26” | Weight |
|
| |
| Glow Boy Shop 300 / |
|
| or Home 300 | 272 lbs. |
| Glow Boy Shop 120 / |
|
| or Home 120 | 225 lbs. |
| 24” |
|
| 46 1/2” |
|
| 8 1/4” |
|
| Exhaust | 31 1/2” |
| + |
|
+ | 8 3/4” |
| 3 3/4” |
|
| |
| Air Inlet | 14 1/4” | Glow Boy Shop 120 / | |
Glow Boy Shop 300 / | Common for | |||
| ||||
or Home 300 |
| all models | or Home 120 |
26” |
|
| 8 1/4” |
| Exhaust |
| + |
+ | 8 3/4” |
3 3/4” |
|
2” Air Inlet | 14 1/4” |
ELECTRICAL SPECIFICATIONS
Electrical Rating | = | 115 | Volts 60 HZ 2.0 Amps |
Watts (operational) | = | 175 (approximately) | |
Watts (optional igniter) | = | 475 | (approximately) |
A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit board will be voided if surge protection is not installed before operating this unit.
If power outages or disturbances are a concern, you may wish to purchase a gas powered generator, solar or battery
EPA COMPLIANCE
This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test methods by Warnock Hersey , US. Pellet appliances that are designed with the combustion air supply ex- ceeding 35:1 (by ratio) are exempt from EPA regulations.
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE.
Glow Boy Home & Shop Heater | www.glowboystoves.com | 8 |
|
|
|