Davis Instruments Vantage Pro2 manual Chapter Troubleshooting and Maintenance, Problem Solution

Models: Vantage Pro2

1 56
Download 56 pages 53.28 Kb
Page 40
Image 40

Chapter 4

Troubleshooting and Maintenance

Vantage Pro2 Troubleshooting Guide

While your Vantage Pro2 weather station is designed to provide years of trouble-free operation, occasional problems may arise. If you are having a problem with your station, please consult this troubleshooting guide before calling Davis technical support. You may be able to quickly solve the problem yourself. If you need help, please see “One Year Limited War- ranty” on page 42.

Note:

Refer to the ISS Installation Manual for additional troubleshooting information.

 

 

 

 

 

 

 

TABLE 4-1: TROUBLESHOOTING GUIDE

 

 

 

 

 

 

 

 

Problem

 

Solution

 

 

 

 

 

 

 

 

Display is blank

Unit is not receiving power. Check the power adapter connections

 

 

and/or replace batteries.

 

 

 

 

 

 

 

ISS not plugged in (cabled station). See ISS manual.

 

 

 

Sensors not transmitting (wireless station). See ISS (or other

 

 

 

 

transmitter) manual.

 

 

Display shows dashes in

Console not receiving (wireless station) - See “Troubleshooting

 

 

 

Reception Problems” on page 38.

 

 

place of weather data

 

 

 

A reading has exceeded the limits indicated in the specifica-

 

Display

 

 

 

tions table.

 

 

play limits. Check calibration number and adjust if necessary.

 

 

 

Calibration numbers may be causing readings to exceed dis-

 

 

 

 

 

 

 

Console is sluggish or does

The console and display may not work below 32º F (0º C). Use an

 

 

External Temperature sensor in low-temperature locations or install

 

 

not work at low temperatures

 

 

the console indoors.

 

 

 

 

 

 

 

 

 

 

 

If the console “locks up”, reset the console by removing AC and bat-

 

 

Display “locks up”

tery power then restoring power. If this occurs frequently in an AC-

 

 

powered console, plug the AC power-adapter into a surge suppres-

 

 

 

 

 

 

sor.

 

 

 

 

 

 

 

 

Humidity

Inside humidity seems too

Make sure the console is not near a humidifier or de-humidifier.

 

Also make sure the console backlight is not on.

 

 

Check calibration number and adjust if necessary. If inside humidity

 

 

high or too low

is low, and inside temperature is too high, see “inside temp” below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For low readings, remove the wind cups and check for friction

 

Speed

Wind speed reading seems

sources. Check the anemometer location. Is it sheltered from the

 

too high or too low.

wind? See ISS manual for additional wind speed troubleshooting

 

 

information.

 

Wind

 

 

 

 

Wind speed reads 0 either all

The problem may be with the anemometer. Test anemometer by

 

 

the time or intermittently

spinning wind cups. Check fields one-b and two-b on diagnostic

 

 

screen and call technical support.

 

 

 

 

 

 

 

 

 

37

Page 40
Image 40
Davis Instruments manual Chapter Troubleshooting and Maintenance, Vantage Pro2 Troubleshooting Guide, Problem Solution