Image 55

Weather Data Specifications

Weather Data Specifications

Variable

Required Sensors

Resolution

Range

Nominal Accuracy

(+/-)

 

 

 

 

 

 

 

 

 

Solar Radiation

Solar sensor

1 W/m2

0 to 1800 W/m2

5% of full scale

Inside

Included in Console

0.1°F; 0.1°C

+32° to +140°F; 0 to

1°F; 0.5°C

Temperature

+60°C

 

 

 

 

 

 

 

 

Outside

ISS, Temp Station

 

-40°to +150°F;

 

or Temp Hum

0.1°F; 0.1°C

1°F; 0.5°C

Temperature***

-40°to +65°C

Station

 

 

 

 

 

 

 

 

 

 

 

 

ISS, Temp Station,

 

 

 

Extra Temperature

Temp Hum Station,

1°F; 1°C

-40°to +150°F

1°F (0.5°C)

Leaf Soil Station or

-40°to +65°C

 

 

 

 

Soil Station

 

 

 

 

 

 

 

 

Heat Index

ISS or Temp/Hum

1°F; 1°C

-40°to +135°F;

3°F (1.5°C)

Station

-40°to +57° C

 

 

 

 

 

 

 

 

Temp-Hum-Sun-

ISS & Solar

1°F; 1°C

-90°to +135°F;

4°F (2°C)

Wind index

Radiation

-68°to +64° C

(THSW)

 

 

 

 

 

 

 

 

 

 

 

Time

Included in Console

1 min

24 hours

8 sec/mon

 

 

 

 

Date

1 day

month/day

8 sec/mon

 

 

 

 

 

 

UV Index

 

0.1 Index

0 to 16

5% of full scale

 

UV Radiation

 

 

 

UV Dose

0.1 MED < 20,

0 to 199 MEDs

5%

 

1 MED > 20

 

 

 

 

Wind Direction

 

1°

0 to 360°

7°

 

 

 

 

 

Compass Rose

 

22.5°

16 compass pts

0.3 compass pt

 

 

 

 

 

Wind Speed (large

 

 

2 to 150 mph;

greater of

 

1 mph; 1 kt; 0.5 m/s;

2 to 130 kts

2 mph/kts;

cups)

Anemometer

1 km/h

3 to 241 km/h,

1 m/s; 3 km/h

 

 

 

1 to 68 m/s

or 5%

Wind Speed (small

 

 

3 to 175 mph;

greater of

 

1 mph; 1 kt; 0.5 m/s;

3 to 150 kts

3mph; 3 kts;

cups)

 

1 km/h

1.5 to 79 m/s

1 m/s; 5km/h

 

 

 

5 to 282 km/h

or 5%

Wind Chill

ISS

1°F; 1°C

-120°to +130°F

2°F;1°C

-84°to +54°C

 

 

 

 

***Outside temperature accuracy is based on the temperature sensor itself and not on the sensor and the passive shielding together. The solar radiation induced error for standard ration shield: +4°F (2°C) at solar noon; for fan aspirated radiation shield: +0.6°F (0.3°C) at solar noon (insolation = 1040 W/m2, avg. wind speed 2 mph (1 m/s), reference: RM Young Model 43408 Fan-Aspirated Radiation Shield).