Vantage Pro2 Troubleshooting Guide

 

 

 

 

 

 

 

TABLE 4-1: TROUBLESHOOTING GUIDE

 

 

 

 

 

 

 

 

Problem

 

Solution

 

 

 

 

 

 

 

Dew

Dew Point reading seems

Check calibration numbers for temperature. Remember, dew point

 

depends on temperature and outside humidity. Make sure they’re

 

too high or too low

 

 

 

working.

 

 

 

Outside temperature sensor

Check calibration number and adjust if necessary. ISS or temp sen-

 

 

reading seems too high

sor may need to be relocated. See ISS or other transmitter manual.

 

 

 

 

 

 

 

 

Move the console out of direct sunlight. Make sure that the console

 

 

 

or sensor is not in contact with an exterior wall that heats up in sun-

 

 

Inside temperature sensor

light or when outside temperature rises. Make sure the console or

 

Temperature

reading seems too high

sensor is not near a heater or other internal heat source (lamps, ap-

 

 

pliances, etc.). Also make sure the console backlight is not on.

 

 

 

Check calibration number and adjust if necessary.

 

 

 

 

 

 

 

Outside temperature seems

Check calibration number and adjust if necessary. Sprinklers may

 

 

too low

be hitting the ISS radiation shield. Relocate. See ISS manual.

 

 

 

 

 

 

 

 

 

Make sure the console or other temperature sensor is not in contact

 

 

Inside temperature sensor

with an exterior wall that cools down when outside temperature

 

 

drops. Make sure the console or other temperature sensor is not

 

 

reading seems too low

 

 

near an air conditioning vent. Check calibration number and adjust

 

 

 

 

 

 

if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction

 

Wireless model - check reception. See Reception Problems

 

Wind direction reading is

 

below.

 

Cabled model - cable may be faulty.

 

 

dashed out

 

 

If these steps do not reveal the problem, the anemometer may be

 

 

 

 

Wind

 

faulty. Call technical support for return authorization.

 

 

 

 

 

Wind direction always says

Usually an ISS problem, especially if outside temperature is dashed

 

 

north

out as well. See the ISS manual for troubleshooting information

 

 

 

 

 

 

 

Chill

Wind chill reading seems too

Check calibration numbers for temperature. Remember, wind chill

 

depends on temperature and wind speed. Make sure they’re work-

 

high or too low

 

 

 

ing.

 

 

 

Heat

Heat Index reading seems

Check calibration numbers for temperature. Remember, the heat in-

 

dex depends on temperature and outside humidity. Make sure

 

too high or too low

 

 

 

they’re working.

 

 

 

 

 

 

 

Rain

No rain readings

Make sure cable-tie is removed from rain collector. See the ISS

 

manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

Incorrect times for sunrise

Check your latitude, longitude, time zone, and daylight savings time

 

settings. Sunrise and sunset times are calculated from the console

 

and sunset

 

 

 

using all of these settings.

 

Troubleshooting Reception Problems

While we have tested the Wireless Vantage Pro2 radio extensively, each site and each installation presents its own issues and challenges. Obstruc- tions, particularly metallic ones, will often cut down your station’s recep- tion distance. Be sure to test reception between the console and ISS, in the locations you intend to install them, or before permanently mounting your ISS or other transmitter(s).

38