The main display generally shows the incoming sample rate, in kS/s, or the mode (DSD). When other parameters are set, it briefly shows the new setting (volume, tone frequency, etc) then reverts to its normal display. In the case of an error condition, it will display an error message.
If the unit is being slaved to a reference source, the display also indicates which reference input it is slaved to.
xxxThe sample rate, in kS/s (32, 44.1, 48, 88.2, 86, 176.4, or 192).
b xxx | Slaved to the BNC Word Clock In. |
r xxx | Slaved to AES Reference In. |
d xxx | Temporary display during locking – the unit has |
| detected the base reference sample rate and is |
| attempting to lock to it. |
. xxx | Temporary display during locking – the unit is lining |
| up word clock out to word clock in. |
Important error messages are given below – a full list is given in the section “Error Codes and Messages” on page 76.
BadFs | The clock source is not in pull in range, or is poorly |
| formatted. The unit cannot lock to it. |
Err.xy | An error has been detected. Please refer to |
| “Internal Device Error Codes” on page 76 for |
| more specific details on error codes. |
Hot | The unit is overheating, probably due to inadequate |
| ventilation. Please check positioning and cooling. |
Ouch | The “Hot” warning has been ignored and the unit is |
| getting so hot that damage may follow. |
(blank) | If the display is completely blank for any significant |
| period, try switching off for 10 seconds then |
| switching on again. If this does not solve the |
| problem, contact your distributor or dCS. |