Sample Alignment
The dCS 954 aligns samples such that Word Clock Out aligns with AES3 samples out (Reference Out), the rising edge of Word Clock Out aligning with the start of the first illegal code in the X,Z subframe preamble and the falling edge aligning with the start of the Y subframe preamble.
Figure 19 – Word Clock and AES3 outputs, 96 kS/s
Figure 20 – Word Clock and AES3 outputs, 44.1 kS/s