(Input Format). Sets the AES input
Auto | The message flags on the selected input are |
| checked and the format is automatically set to |
| Single, Dual or Quad AES. Dual AES must be |
| connected to AES 1 & 2 or AES 3 & 4. |
US[1] | |
US[2] | |
US[4] | User selected Quad AES mode. |
You can
In Dual or Quad AES modes, the unit will warn you of missing wires with a display like
(Filter). Selects one of several
A typical audio signal contains very little signal energy above 10kHz, so there is some justification for relaxing the filter attenuation as 20kHz is approached.
DSD mode also has four filters. Metering DSD is difficult because the high level of ultrasonic noise can cause spurious meter readings. DSD Filt4 is specially designed for metering the 0 – 20kHz band and may not give the best sonic performance.
BNC I
(BNC Inputs). In PCM mode, this sets the format of the BNC In connectors.
SDIF | Configures Ch1, Ch2 and Clk In as an |
| interface. |
AES | Configures Clk In to accept AES3 encoded data at |
| TTL levels at up to 96kS/s. |
Select these inputs using the BNC button.
If the unit is already locked to SDIF or DSD, the AES option is disabled.