IMPORTANT! If the Non Audio flag is stripped by the recorder and the dCS 954 is not set to DSD mode, it will accept DSD data as AES3 PCM and will output potentially damaging full scale noise.
If you connect DSD to the SDIF input and select it while DSD mode is Off, the unit will remain muted, identify the format, automatically select DSD mode and unmute.
If you connect SDIF while DSD mode is On, the unit will remain muted until you set DSD mode to Off.
To use P3D mode (assuming your hardware is suitable), first set the DSD menu option to dSd3. Connect the
Runs a display self test routine. When successfully completed, the unit displays Pass and returns to normal operation. Otherwise an error message Err.xy is displayed – please refer to “Error Codes and Messages” on page 76 for more specific information.
DataReads and displays the message information from an incoming AES/EBU data stream. This provides a simple access to the digital audio message bits for reference or to assist with system debugging. There are separate data sets for Professional and Consumer streams - the unit reads the incoming stream and decides which it is. Pressing Set again steps through the message fields (see the Appendix for a fuller listing of what these are):
First field | Professional use channel status block, or ... | |
Pro | ||
Con | Consumer use channel status block. | |
Second field | Audio data, or ... |
|
Audio |
| |
n.Aud |
| |
Third field | Emphasis not indicated, or... | |
N Ind | ||
None | No emphasis, or ... |
|
50 15 | 50/15∝s emphasis, or ... |
|
J. 17 | CCITT J.17 emphasis, or ... | |
D | Unable to decode emphasis, or ... | |
CPY P | Copy prohibit, or ... |
|
CPY E | Copy enable. |
|
Fourth field | Encoded sample rate is “xxxx”, i.e. 32, 44.1, 48, | |
Exxxx | ||
| 88.2, 96, 176.4 0r 192kS/s. | |
| may only decode the first 3 options. or ... | |
Unknown encoded sample rate. | ||
Fifth field |
|
|
|
|
|
Manual part no: DOC136954 iss 2B1 | Page 21 | file 135954ma2b1.pdf available from website |