dCS 954 User Manual |
| Manual for Standard Software Version 1.5x | ||||
dCS Ltd |
|
|
| June 2000 | ||
|
|
|
|
|
|
|
Digital Interface Specifications |
|
|
|
|
| |
|
|
|
|
|
|
|
| AES/EBU (AES3) |
| Input | Output |
|
|
| Type |
| Balanced, differential |
|
| |
| Impedance |
| 110 | 110 | Ω |
|
| Sensitivity (unloaded) |
| 1 ~ 10 | 7 | V |
|
| Maximum Wordlength |
| 24 | 24 | bits |
|
| Damage level |
| > 20 |
| V |
|
| Connector |
| XLR3 female | XLR3 male |
|
|
| Connections | Pin 1 | Ground or shield |
|
| |
|
| Pin 2 | +Signal |
|
| |
|
| Pin 3 |
|
| ||
Table 4 – AES/EBU i/o specifications
Input | Output |
|
| |
DSD |
|
|
|
|
Type | Single ended, ground |
|
| |
| referred |
|
| |
Impedance | 100 | 25 |
| Ω |
Sensitivity (unloaded) | TTL | TTL |
|
|
Maximum Wordlength | 24 | 24 |
| bits |
Damage level | > 10 |
|
| V |
Time skew |
|
|
|
|
Word Clock in / out | < 40 |
|
| ns |
Connector | BNC x 3 | BNC x 1 |
|
|
Connections | CH1 (left) |
|
| |
| CH2 (right) |
|
| |
| Clk In & Out |
|
| |
Table 5 – |
| |||
| Remote control interface | Input / Output | ||
Type |
|
|
|
|
| ||
Level |
|
| |
Baud Rates |
| 1200, 2400, 4800, 9600 |
|
Data Format |
| Contact dCS |
|
Connector |
| 9 way D type male |
|
Table 6 – Remote Control Interface Details
Manual part no: DOC136954 iss 2B1 | Page 45 | file 135954ma2b1.pdf available from website |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |