dCS 954 User Manual | Manual for Standard Software Version 1.5x |
dCS Ltd | June 2000 |
System Messages and Error Codes
Some other messages may be displayed that give indications of errors from other sources (outside the unit):
Display | Description |
n.Aud |
|
The data has been flagged by an AES3 message as Non | |
| Audio (perhaps a CD ROM). This message may also be |
| displayed briefly when the sample rate is changed (see |
| page 22) |
Hot | The unit is overheating, and performance may suffer.(see |
| page 66) |
Ouch | The unit is seriously overheating, and may be damaged |
| shortly. Switch off! (see page 66) |
Bad Fs | The sample rate coming in is not one the unit can lock to, |
| or there is an input signal quality problem.(see page 39) |
CRC | P3D error message only, if the data coming in does not |
| pass the CRC data integrity check (see page 55) |
| Table 14 – System Error Codes |
Trouble Shooting Your System
If you experience difficulties when using your dCS 954, the following suggestions may help to resolve the problem.
The unit fails to power up•Ensure there is power available on the mains cable and the unit’s mains switch is On.
•Check the rated supply voltage shown on the rear of the unit matches the local supply voltage.
•Check that the fuse has not blown - if so, correct any obvious cause then replace the fuse as described in the section “User Changeable Parts”, page 72.
•Check that the mains cable is pushed fully home into the mains inlet in the rear of the unit.
The unit fails to lock to a source•Ensure the correct input is selected and the Ref In menu item is set to
Route.
•Check that the digital audio cable is of the correct type, correctly connected and not damaged. Damaged cables are a VERY common cause of malfunctions!
•Check that the source is switched on.
•Some CD players do not generate a digital output unless the disc is playing - set the player in “play” mode and check that the unit locks.
•If you are using
Manual part no: DOC136954 iss 2B1 | Page 77 | file 135954ma2b1.pdf available from website |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |
(inside the UK replace + 44 with 0) | web site: www.dcsltd.co.uk |