BNC
(BNC Button). In PCM mode, this controls the operation of the BNC button.
Input | Configures the BNC input connectors as a data |
| input. Press the BNC button to select it. |
RefCl | Configures the BNC word clock in (Clk In) |
| connector as a reference clock input. Press the |
| BNC button to sync the unit to the Word clock |
| while taking data from one or more of the AES |
| inputs. The BNC LED will light, in addition to the |
| LED(s) for the data source. Press the BNC button |
| again to sync to the data input instead. |
This mode of operation enable the unit to sync to one clock source and rapidly switch between other synchronous sources without going through a PLL locking sequence. It might be used, for example, in A/B comparisons or in locking to a house sync, just taking data from AES feeds.
If the unit is already locked to SDIF or DSD, the RefCl option is disabled.
BNC O(BNC Output). In PCM mode, this sets the format of the BNC Out connector (Clk Out).
SDIF | Sends out SDIF Word Clock on the Clk Out |
| connector. The unit must be locked to generate an |
| output. |
AES | Sends out AES3 coded data at TTL levels, at up to |
| 96 kS/s on the Clk Out connector. This works |
| when the unit is locked to Single AES, SDIF or |
| BNC - AES input. |
Panel |
|
(Panel Control). Sets the operation of the Phase and | |
Phase | Sets the two buttons to their standard functions. |
Vol | The two buttons act as a digital volume control. |
| Phase reduces the Volume in 0.1dB steps, while |
dCS telephone number scrolls across the display.
FacsdCS fax number scrolls across the display
PartThe control board part number (version) scrolls along the display.
Manual part no: DOC136954 iss 2B1 | Page 27 | file 135954ma2b1.pdf available from website |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |