Menu Items
IssueDisplays the software issue when Set is pressed.
DSD
Selects DSD mode. When on and locked, the unit displays “dSd”. This mode takes about 15 seconds to load, during which time the menu cannot be used. There are two options:
Off | The unit operates in PCM mode. |
On | The unit will accept either DSD via the SDIF input |
| connectors (automatically selecting |
| |
| 44.1kS/s links. |
P3D units have a slightly more explicit menu sequence for this item:
Off | The unit operates in PCM mode. |
P3D | The unit will accept DSD via the SDIF input |
| connectors (automatically selecting |
| |
| connectors |
DSD4 | The unit will accept DSD via the SDIF input |
| connectors (automatically selecting |
| |
| 44.1kS/s links. |
To select DSD on the SDIF inputs, first set the dSd menu option to On. Connect the 2 data lines plus a 44.1kS/s Word Clock and press the BNC button. The LED above the button will brighten and the display will show dSd.
To select
DSD is so different from PCM that many of the PCM related features are no longer appropriate or are not implemented.
-the Mute and Coarse Lock buttons operate as usual
-the Phase and
-the Volume control is disabled.
-the following Menu items are disabled or have their functions locked: Data,
Filt works – there are 4 filter options in DSD mode. See the section on “DSD” starting on page 40 for more details – they