Dell 1600SC manual Guide

Models: 1600SC

1 100
Download 100 pages 38.89 Kb
Page 30
Image 30

Keyboard stuck key failure

Faulty or improperly installed memory modules.

See "Troubleshooting System Memory" in "Troubleshooting Your

 

System."

Memory address line failure at address, read value expecting value

Memory double word logic

 

 

failure at address, read

 

 

value expecting value

 

 

 

 

 

Memory odd/even logic failure

 

 

at start address to end

 

 

address

 

 

 

 

 

Memory write/read failure at

 

 

address, read value expecting

 

 

value

 

 

 

 

 

 

Faulty application program.

Restart the application program.

Memory allocation error

 

 

 

 

 

 

Memory module installation guidelines have not

See "Memory Module Installation Guidelines" in "Installing System

 

been properly followed.

Options."

Memory bank population error!

 

 

 

Faulty or improperly installed memory modules.

See "Troubleshooting System Memory" in "Troubleshooting Your

 

 

System."

Memory parity interrupt at

 

 

address

 

 

 

 

 

 

The spacebar was pressed during POST to

Information only.

 

terminate the memory test.

 

Memory tests terminated by

 

 

keystroke

 

 

 

 

 

 

Faulty diskette, diskette drive, CD drive, or hard

Use a bootable diskette, CD, or hard drive. If the problem persists,

 

drive.

see "Troubleshooting the Diskette Drive," "Troubleshooting a CD

No boot device available

 

Drive," and "Troubleshooting Hard Drives" in "Troubleshooting Your

 

System."

 

 

 

 

 

 

No operating system on hard drive.

Check the hard-drive configuration settings in the System Setup

 

 

program (see "Using the System Setup Program" in your User's

No boot sector on hard- disk

 

Guide).

 

 

drive

 

 

 

 

 

 

Faulty system board.

See "Getting Help."

No timer tick interrupt

 

 

 

 

 

 

Faulty diskette, diskette drive, CD drive, or hard

See "Troubleshooting the Diskette Drive," "Troubleshooting a CD

 

drive.

Drive," and "Troubleshooting Hard Drives" in "Troubleshooting Your

Non-system disk or disk error

 

System." If the problem persists, see "Getting Help."

 

 

 

 

 

 

No operating system on diskette.

Use a bootable diskette.

Not a boot diskette

 

 

 

 

 

 

Microprocessors with different speeds are installed.

Replace the slower microprocessor with one that matches the

 

System operates at speed of slower microprocessor. faster microprocessor.

One value1 MHz Processor, L2

 

 

Cache: 512KB

 

 

One value2 MHz processor, L2

 

 

Cache: 512KB

 

 

System running at value1 MHz

 

 

 

 

 

 

Loose cables to expansion card(s); faulty or

Ensure that all appropriate cables are securely connected to the

 

improperly installed expansion card.

expansion cards. If the problem persists, see "Troubleshooting

PCI BIOS failed to install

 

Expansion Cards" in "Troubleshooting Your System."

 

 

 

 

 

 

Error encountered while initializing PCI devices.

Install the NVRAM-clear jumper and reboot the system (see

 

 

Figure A-2 for jumper location). If the problem persists, see

Plug & Play Configuration

 

"Troubleshooting Expansion Cards" in "Troubleshooting Your

 

System."

error

 

 

 

 

 

 

 

The primary IDE channel is enabled in the System

Run the System Setup program to correct the drive settings (see

 

Setup program, but no drive is attached; improperly

"Using the System Setup Program" in your User's Guide). If the

Primary drive n not found

installed hard drive; loose interface or power cable.

problem persists, see "Troubleshooting Hard Drives" in

 

"Troubleshooting Your System."

 

 

 

 

 

 

Faulty diskette, diskette drive, CD drive, tape drive,

See "Troubleshooting the Diskette Drive," "Troubleshooting a CD

Page 30
Image 30
Dell 1600SC manual Guide