7DEOH&RGH￿￿￿￿

6\VWP&DXVH%HHS&RGHV

&RUUHFWLYH$FWLRQ

 

 

 

1-1-3

NVRAM write/read

Replace the system board.

 

failure

 

 

 

 

1-1-4

BIOS checksum

Replace the system board.

 

failure

 

 

 

 

1-2-1

Programmable

Replace the system board.

 

interval-timer failure

 

1-2-2

DMA initialization

 

 

failure

 

1-2-3

DMA page register

 

 

write/read failure

 

 

 

 

1-3-1

Main-memory

Remove and reseat the DIMMs. If

 

refresh verification

the problem persists, replace the

 

failure

memory module.

 

 

 

1-3-2

No memory installed

Remove and reseat the DIMMs.

 

 

Reboot the system. If the problem

persists, replace the memory module.

1-3-3 Chip or data line fail- ure in the first 64 KB of main memory

1-3-4 Odd/even logic fail- ure in the first 64 KB of main memory

Remove and reseat the DIMMs. Reboot the system. If the problem persists, replace the memory module.

1-4-1 Address line failure in the first 64 KB of main memory

1-4-2 Parity failure in the first 64 KB of main memory

2-1-1 Bit failure in the first through 64 KB of main

2-4-4 memory

3-2 Dell PowerEdge 6350 Systems Service Manual

Page 46
Image 46
Dell 6350 manual Ruuhfwlyh$Fwlrq