7DEOH&RGH￿￿￿￿

6\VWP&DXVH%HHS&RGHVFRQWLQXHG&RUUHFWLYH$FWLRQ

 

 

 

4-3-3

Defective system

Replace the system board.

 

board

 

 

 

 

4-3-4

Time-of-day clock

Replace the battery. If the problem

 

stopped

persists, replace the system board.

 

 

 

4-4-1

Faulty I/O chip

Replace the system board.

 

Super I/O controller

 

 

failure

 

 

 

 

4-4-2

Parallel-port test

Replace the system board.

 

failure (defective

 

 

system board)

 

 

 

 

4-4-3

Math coprocessor

Replace the microprocessor.

 

failure (defective

 

 

microprocessor)

 

 

 

 

4-4-4

Cache test failure

Replace the microprocessor.

 

(defective

 

 

microprocessor)

 

 

 

 